L1713S04-AZ00-000 [Carling Technologies]
Rocker Switch, SPDT, On-off-(on), Momentary, Quick Connect Terminal, Rocker Actuator, Panel Mount;型号: | L1713S04-AZ00-000 |
厂家: | Carling Technologies |
描述: | Rocker Switch, SPDT, On-off-(on), Momentary, Quick Connect Terminal, Rocker Actuator, Panel Mount 光电二极管 |
文件: | 总12页 (文件大小:1443K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
L-Series
Switch
The L-Series rocker switch is an innovative product offering
total design flexibility, while at the same time setting new
standards for performance and reliability. Its versatile design
features include a neatly proportioned size that fits into an
industry standard mounting hole of 1.734 x .867 (44.0mm
x 22.0mm), countless unique choices for ratings, circuits,
colors, illuminations and laser etched legends. These single or
double pole switches also feature a broad choice of actuator
styles, colors, and lenses with up to twelve terminals offering
an extensive range of switch and lamp circuit options,
including LED or incandescent illumination. Additionally, an
optional plug-in terminal connector enables pre-wiring of
wire your harness.
Performance Features:
Typical Applications:
IP67 certified sealed front panel components
Withstands temperatures from -40°C to +85°C
Vibration, shock, thermoshock, moisture and salt spray
resistant
Construction machinery
Agricultural equipment
On-highway transportation equipment
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
|
2
L–Series Sealed Rocker Switches
L-Series Switch
DESIGN FEATURES
LED LAMPS
SEAL PROTECTION
TERMINALS
Utilize less current and are not
affected by vibration, providing
long lasting illumination.
Available in 3 standard colors.
Locks out elements such as
water, dust & debris. Certified
to IP67 for front panel
components.
Available with 2 industry
standard termination options:
.250 or .187 tabs with up to 12
terminal options.
LENS & LEGENDS
ACTUATOR
ROLLER PIN
BASE
Lens available in 2 sizes and 6
standard colors in either translucent
or transparent materials. Numerous
symbols and text available for
imprinting or laser etching.
Available in rocker or
paddle styles. Several
standard color options
also available.
Eliminates need for
Fits into industry
standard mounting
hole of 1.734 x .867 in
[44.0mm x 22.0mm].
lubricants, increasing the
temperature range of the
switch from -40˚ C to +85˚C
[-40˚ F to 185˚ F].
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
L–Series Sealed Rocker Switches - General Specifications
3
Electrical
Environmental
Contact Rating
.4VA @ 24VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
Environmental
IP67 for above panel components
of the actual switch, representing
an index of protection as applied
to electrical equipment in
accordance with IEC 529, BS
5490, DIN 400 50 & NFC 20 010.
Mixed Flowing Gas MFG Class III
per ASTM B-827 & B-845, Method
H, with 3 years exposure.
-40°C to + 85°C
Per Mil-Std 202F, Method 204D
Test Condition A 0.06 DA or
10G’s 10-500 Hz. Tested with VCH
connector. Test criteria - No
loss of circuit during test and pre
and post test contact resistance.
Resonance search
20 amps, 4-14VDC
15 amps, 15-28VDC
1250 Volts RMS between pole to
pole
3750 Volts RMS between live
parts and accessible surfaces
50 Megaohms
Dielectric Strength
Corrosion
Operating Temperature
Vibration 1
Insulation Resistance
Initial Contact Resistance 10 milliohms max. @ 4 VDC
Life
100,000 cycles maintained,
50,000 cycles momentary at rated
voltage and current
90/10 silver-nickel, silver tin-oxide,
gold
Brass or copper/silver plate
3/16” (4.76mm) & 1/4” (6.3mm)
Quick Connect terminations
standard.
Contacts
Terminals
Vibration 2
24-50 Hz 0.40 DA
50-2000 ±10 G’s peak
Results Horizontal Axis 3-5 G’s
max.
Random
24 Hz
0.06 PSD-Gsq/Hz
60 Hz
100 Hz
200 Hz
0.50
0.50
0.025
Mechanical
Endurance
250,000 cycles minimum
2000 Hz 0.025
No loss of circuit during test; <10µ
chatter.
Physical
Lighted
Shock
Per Mil-Std 202F, Method 213B,
Test Condition K @ 30G’s. Tested
with VCH connector. Test criteria
- No loss of circuit during test,
pre, and post test contact
resistance.
Per Mil-Std 202F, Method 101D,
Test Condition A, 48 Hrs.
Per Mil-Std 202F, Method 107F,
Test Condition A, -55°C to 85°C.
Test criteria - pre and post test
contact resistance.
Incandescent - rated 10,000
hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for
voltages to 24 VDC)
Rocker, base & bracket are
sealed.
Nylon 66 GF rated to 85°C with a
flammabilityꢀratingꢀofꢀ94V0.
Basic actuator structure molded
of thermoplastic polycarbonate
with a hard Nylon 66
Salt Spray
Seals
Thermal Shock
Base
ꢀ
Actuator
Moisture Resistance
Per Mil-Std 202F, Method 106F,
Test Criteria - pre and post test
contact resistance.
thermoplastic surface overlay.
Acetal
Lock
Lens
Polycarbonate rated at 100°C
2 & 3 Position Rocker Style
Nylon Zytel
Mounting Specifications
Function
Bracket
Connector
.867 [22.02]
Nylon 66 rated at 85°C. Polarized.
TEST CUT
HOLE IN
1.734 [44.04]
ACTUAL
MATERIAL
Actuator Travel (Angular Displacement)
2 position
3 positions
26°
MOUNTING HOLE
13° from center
Panel Thickness Range
Acceptable Panel Thickness
.030 to .156 (.76mm to 3.96mm)
Recommended:
.030, .062, .093, .125 and .156
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
4
L-Series Sealed Rocker Switches – Ordering Scheme
L 11 E 3 C H N 1 3 A A 45 1 48
8
9
10
11
12
13
Legend
Orientation Lens Legend
14
Actuator
1
2
3
4
5
6
7
Bracket
Actuator
Lens Style Lens Style Legend
& Color & Color
Series
Circuit
Rating
Termination Illumination Lamp
Lamp
1 SERIES
L
5 ILLUMINATION
Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end
of switch. Positive (+) and negative (-) symbols apply to LED lamps only.
Lamps
NONE
# 1
Illumination Type
Lamp wired to Terminals
2 CIRCUIT2
S
A
B
C
Independent
Independent
Independent
Independent
Dependent
Independent
Dependent
Independent
Dependent
Dependent
Independent
Both Independent
(in series)
10+ 9-
12+ 11-
10+ 9-
12+ 9-
Terminal Orientation
( ) - momentary
# 2
SP - single pole - uses terminals 1, 2 & 4.
DP - double pole uses terminals 5, 6 & 8.
Terminals 9, 10 & 11 for lamp circuit only.
# 1
& # 2
# 1
# 1
& # 2
# 1
& # 2
# 1
& # 2
# 1
& # 2
# 1
& # 2
# 2
# 1
D
E
4+
10+ 9-
4+ 9-
10+ 9-
9-
4
F
G
H
J
Position:
1
2
3
8+
4+
9-
9-
SP
11
12
13
14
15
16
17
18
DP
21
22
23
24
25
26
27
28
2 & 4, 6 & 8
ON
Connected Terminals
1 & 2, 5 & 6
OFF
OFF
(OFF)
ON
NONE
NONE
NONE
NONE
NONE
OFF
10+ 9-
10+ 9-
(ON)
ON
ON
ON
(ON)
ON
(ON)
(ON)
Dependent
Dependent
Hazard
4+
1+
6+
6+
9-
ON
9-
ON
OFF
OFF
1
2
10-
10-
12-
12-
(ON)
Hazard
CIRCUITS WITH JUMPER TERMINALS
30*
31
(2,4&5), (1,6&8)
1, 2 & 5
OFF, OFF
2, 3 & 7
(1,2&8), (4,5&6)
2, 4 & 8
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
PROGRESSIVE CIRCUITS
Selection 6: above terminals 10 & 9; Selection 7: above terminals 12 & 11
51
52
53
54
55
56
57
58*
61
62
63
64
65
66
67
68
69*
70
71
72
73
80
3 & 4
2 & 3
1 & 2
No lamp
Incandescent
LED*
2VDC
6VDC
12VDC
24VDC
0
3 & 4
2 & 3
OFF
4 3V
Red
A
B
C
5 6V
Amber
L
M
N
P
6 12V
Green
F
G
H
J
7 18V
8 24V
(3 & 4)
2 & 3
1 & 2
(3 & 4)
2 & 3
OFF
(3 & 4)
2 & 3
(1 & 2)
(3 & 4)
2 & 3
(OFF)
3 & 4
2 & 3
(OFF)
2 & 4
2 & 3
1 & 2
D
3 & 4, 7 & 8
3 & 4, 7 & 8
(3&4), (7&8)
(3&4), (7&8)
(3&4), (7&8)
(3&4), (7&8)
3 & 4, 7 & 8
2 & 4, 7 & 8
2 & 4, 1, 7 & 8
(2&4), (7&8)
(2&4), (7&8)
2 & 4, 7 & 8
(2&4), (7&8)
2 & 4, 6 & 8
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 4, OFF
2 & 4, OFF
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, OFF
2 & 4, OFF
1 & 2, 5 & 6
OFF, OFF
1 & 2, 5 & 6
OFF, OFF
(1 & 2), (5 & 6)
(OFF, OFF)
(OFF, OFF)
OFF, OFF
OFF, OFF
(1 & 2), (5 & 7)
1 & 2, 5 & 7
1 & 2, 5 & 7
OFF, OFF
OFF, 5 & 6
* Consult factory for “daylight bright”, blue/green and white LED options.
Typical current draw for LED is 20ma.
8 BRACKET COLOR1
Black
1
White
2
Gray
3
Red
4
Standard Bracket
Rockerguard at Lamp 1
Rockerguard at Lamp 2
A
E
B
F
C
G
D
H
9 ACTUATOR STYLE AND COLOR1
Black
White
B
Gray
C
Red
D
M
Laser Etched
3
4
HAZARD WARNING CIRCUITS
Rocker
Paddle
A
A2
A3
6,7&8,3&4
6,7&8,2&4
NONE
NONE
OFF, 1 & 2
OFF, 1 & 2
J
N
K
* Available with ratings 1, 4, & E only.
10 & 11 LENS STYLE AND COLOR
Lens color for LEDs must be clear, white, or match color of LED.
0 - No Actuator Z - No Lens
3 RATING2
1
.4VA @ 28VDC Resistive
Clear
1
-
3
-
White
-
7
-
9
A
Amber
Green
Red
M
N
P
R
Blue
4
10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings
B
C
D
E
-
G
H
J
K
-
T
U
V
Large Transparent
Large Translucent
Bar Transparent
W Bar Translucent
- Laser Etched background color
B
C
D
E
G
H
15A 24V
20A 18V
20A 12V
15A 12V
20A 6V
5
-
20A 3V
12 LASER ETCHED, LENS OR BODY LEGEND
4 TERMINATION2,3
00
No legend this location / no actuator
For legend options & codes, visit us at carlingtech.com
1
3
.250 (6.4mm) TAB (QC)
.187 (4.7mm) TAB (QC)
Orientation
1
13 LEGEND ORIENTATION
Notes:
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1 - vertical, lamp 1 on top
Consult factory to verify horsepower rating for your particular circuit choice.
1
2
3
4
Custom colors are available. Consult factory.
Orientation 2 - horizontal, lamp 1 on right
Orientation 3 - vertical, lamp 1 on bottom
Orientation 4 - vertical, lamp 1 on left
Circuits 30, 31, 58, 69 are not available with rating codes 4, C, D, G or H.
Termination 3 only available with rating codes 1, B, and E.
Not available with circuits 11-18, 51-57 and 69.
AA
46
46
AA
3AA-146
3AA-246
Orientation
3
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
For legend options & codes, visit us at carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
L-Series Sealed Locking Rocker Switches – Ordering Scheme
5
L 11 D 1 S W C J P M H 00 0
8
9
10
Lens
11
Lock
12
Legend
13
1
2
3
4
5
6
7
Bracket
Actuator
Legend
Orientation
Series
Circuit
Rating
Termination Illumination Lock
Lamp
1 SERIES
L
6 LOCK
W
Lock above terminals 10 & 9.
2 CIRCUIT5
7 LAMP
Terminal Orientation
( ) - momentary
Above terminals 12 & 11
No lamp
0
SP - single pole - uses terminals 1, 2 & 4.
DP - double pole uses terminals 5, 6 & 8.
Terminals 9, 10 & 11 for lamp circuit only.
Incandescent 4 3V
5 6V
Amber
6 12V
Green
F
G
H
J
7 18V
8 24V
LED*
Red
2VDC
A
B
C
D
L
6VDC
M
N
P
12VDC
24VDC
Position:
1
2
3 (Lock location)
SP
11
14
16
17
18
DP
21
24
26
27
28
2 & 4, 6 & 8
ON
Connected Terminals 1 & 2, 5 & 6
* Consult factory for “daylight bright”, blue/green and white LED options.
Typical current draw for LED is 20ma.
NONE
NONE
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
(ON)
(ON)
8 BRACKET COLOR1
(ON)
J
Black
CIRCUITS WITH JUMPER TERMINALS
302
(2,4&5), (1,6&8) OFF, OFF
1, 2 & 5
(1,2&8), (4,5&6)
2, 4 & 8
312
2, 3 & 7
9 ACTUATOR STYLE AND COLOR1
PROGRESSIVE CIRCUITS
51
52
53
54
55
56
57
58
61
62
63
64
65
66
67
68
69
70
71
72
73
80
3 & 4
2 & 3
1 & 2
Black Red
3 & 4
2 & 3
OFF
Locking Rocker
P
R
(3 & 4)
2 & 3
1 & 2
(3 & 4)
2 & 3
OFF
(3 & 4)
2 & 3
(1 & 2)
(3 & 4)
2 & 3
(OFF)
10 LENS STYLE AND COLOR
Lens color for LEDs must be clear, white, or match color of LED.
0 - No Actuator Z - No Lens
3 & 4
2 & 3
(OFF)
2 & 4
2 & 3
1 & 2
3 & 4, 7 & 8
3 & 4, 7 & 8
(3&4), (7&8)
(3&4), (7&8)
(3&4), (7&8)
(3&4), (7&8)
3 & 4, 7 & 8
2 & 4, 7 & 8
2 & 4, 1, 7 & 8
(2&4), (7&8)
(2&4), (7&8)
2 & 4, 7 & 8
(2&4), (7&8)
2 & 4, 6 & 8
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 4, OFF
2 & 4, OFF
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, OFF
2 & 4, OFF
1 & 2, 5 & 6
OFF, OFF
1 & 2, 5 & 6
OFF, OFF
(1 & 2), (5 & 6)
(OFF, OFF)
(OFF, OFF)
OFF, OFF
OFF, OFF
(1 & 2), (5 & 7)
1 & 2, 5 & 7
1 & 2, 5 & 7
OFF, OFF
OFF, 5 & 6
Clear White Amber Green Red Blue
1
-
3
-
-
7
-
B
C
D
E
G
H
J
M
N
P
T
U
V
Large Transparent
Large Translucent
Bar Transparent
9
K
R
W Bar Translucent
11 LOCK FUNCTION AND COLOR
Locking Position
Up
A
B
C
D
Down Up & Down Center3 Lock Color
H
J
R
S
T
1
2
3
4
5
Match Actuator
Black
White
Red
Safety Orange
3 RATING5
K
L
M
V
W
1
4
.4VA @ 28VDC Resistive
10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings
E
B
C
D
E
G
H
15A 24V
20A 18V
20A 12V
15A 12V
20A 6V
12 LASER ETCHED, LENS OR BODY LEGEND
00
No legend this location / no actuator
For legend options & codes, visit us at carlingtech.com
20A 3V
ORIENTATION OF
ACTUATOR/LENS IN PANEL
13 LEGEND ORIENTATION
4 TERMINATION4
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1 - vertical, lamp 1 on top
ORIENTATION 1
1
3
.250 (6.4mm) TAB (QC)
.187 (4.7mm) TAB (QC)
LOCK
Orientation 2 - horizontal, lamp 1 on right
Orientation 3 - vertical, lamp 1 on bottom
Orientation 4 - vertical, lamp 1 on left
P
5 ILLUMINATION2
Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end
of switch. Positive (+) and negative (-) symbols apply to LED lamps only.
LOCK
PZAY2-2
LOCK
P
P
Lamps
NONE
# 2
Illumination Type
Lamp wired to Terminals
P
LOCK
P
S
B
P
LOCK
12+ 11-
Independent
PZAY2-1
LOCK
Notes:
ORIENTATION
3
Consult factory to verify horsepower rating for your particular circuit choice.
1
2
3
4
5
Custom colors are available. Consult factory.
Additional lamp circuits available. Consult factory.
Available only with 3 position circuits.
Termination 3 only available with ratings 1, B and E.
Circuits 30, 31, 58 and 69, are not available with rating codes 4, C, D, G or H.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
6
L-Series Sealed Rocker Switches – Dimensional Specifications in. [mm]
Dimensional Specifications: in. [mm]
L-SERIES
L-SERIES
SHOWN WITH ROCKER GUARD
SHOWN WITH LASER ETCHED
ACTUATOR
1.970 [50.04]
1.020 [25.91]
.400 [10.16]
.435 [10.16]
1.450 [36.83]
.855 [21.72]
L-SERIES
L-SERIES
SHOWN WITH LARGE LENS
AND PADDLE ACTUATOR
SHOWN WITH BAR LENS, LOCK
AND CONNECTOR
1.970 [50.04]
1.020 [25.91]
.453 [11.51]
.400 [10.16]
3
3
2
2
1 10
1 10
12 4
2.380 [60.45]
12 4
Connector
Hole Plug
L-SERIES
L-SERIES
HOLE PLUG
CONNECTOR
REMOVABLE HOLE PLUG
WITH NON-SERRATED WINGS
LH1
LH2
LC1-01 BLACK .250 TAB CONNECTOR (PACKARD 630 SERIES)
LC2-01 BLACK .187 TAB CONNECTOR (PACKARD 480 SERIES)
LC3-01 BLACK .250 TAB CONNECTOR (AMP ONLY)
1.970 [50.04]
HOLE PLUG WITH
SERRATED WINGS
1.020 [25.91]
.500 [12.70]
1.325 [33.66]
.300 [7.62]
.920 [23.37]
.855 [21.72]
1.710 [43.43]
.790 [20.07]
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
L-Series Sealed Rocker Switches – Dimensional Specifications in. [mm]
7
Dimensional Specifications: in. [mm]
+.008
-.000
+.008
-.000
.984 [25.00]
2.020 [51.31]
R .093 MAX TYP
R .093 MAX TYP
MOUNTING PANEL
TEST
CUT
HOLE IN
ACTUAL
MATERIAL
TEST
CUT
HOLE IN
ACTUAL
FOR ADDITIONAL UNITS, ADD 1.03 [26.2] PER UNIT.
FOR MORE THAN 2 L-SERIES SWITCHES, ADD MIDDLE
SECTION. AVAILABLE IN PANEL THICKNESSES LISTED
BELOW. CONSULT FACTORY
+.008
-.000
1.900 [48.26]
+.008
-.000
1.900 [48.26]
MATERIAL
DIMENSIONS: LME 2.02 [51.3mm] PLUS NUMBER OF
CENTER BEZELS (LMM) X 1.034 [26.26mm]
MOUNTING PANEL THICKNESS
.062 [1.57]
LMS
MOUNTING PANEL
.093 [2.36]
MOUNTING PANEL
HOLE
OPENING
(2) UNITS
.125 [3.17]
.156 [3.96]
2.300 [58.42]
1.187 [30.15]
2.300 [58.42]
1.990 [50.55]
2.300 [58.42]
1.030 [26.16]
LMM MOUNTING PANEL
1.340 [34.04]
LME MOUNTING PANEL
LMS
END
MIDDLE
MOUNTING PANEL
1.700 [43.18]
1.030 [26.16]
1.030 [26.16]
.670 [17.02]
2.300 [58.42]
2.300 [58.42]
3.400 [86.36]
LM3 MOUNTING PANEL
4.430 [112.52]
LM4 MOUNTING PANEL
PANEL OPENING SIZE: 1.90 X 4.09 [48.3mm X 103.9mm]
PANEL OPENING SIZE: 1.90 X 3.06 [48.3mm X 77.7mm]
1.030 [26.16]
.670 [17.02]
2.300 [58.42]
6.490 [164.85]
LM6 MOUNTING PANEL
PANEL OPENING SIZE: 1.90 X 6.15 [48.3mm X 156.2mm]
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
8
L-Series Switch – Circuit Diagrams
CIRCUIT
CODE
CIRCUIT
SCHEMATIC
CODE
CIRCUIT
CODE
SCHEMATIC
4
SCHEMATIC
3
5
4
1
2
11
22
51
2
6
2
4
3
4
4
5
12
23
24
25
52
53
54
2
2
1
4
3
6
2
1
4
5
8
4
13
2
2
2
4
3
6
1
4
1
4
5
8
14
15
2
2
2
2
2
2
2
2
1
4
3
6
1
4
8
1
1
1
5
4
26
55
2
2
4
3
6
4
4
4
4
1
4
5
8
16
17
27
28
56
57
2
4
3
2
6
1
4
5
8
6
2
2
4
4
1
1
4
3
2
8
1
5
18
21
30
31
58
61
6
7
2
3
1
5
7
3
8
1
4
5
8
6
2
6
8
4
2
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
L-Series Switch – Circuit Diagrams
9
CIRCUIT
CODE
CIRCUIT
CODE
SCHEMATIC
SCHEMATIC
3
7
1
5
4
8
62
63
64
65
66
67
68
69
70
71
72
73
80
81
2
4
6
8
7
2
1
5
4
8
1
5
3
7
7
2
2
4
6
8
7
33
4
8
7
2
2
4
6
8
7
5
4
8
1
5
3
6
2
2
4
6
8
7
3
4
5
8
1
6
2
2
4
3
6
8
7
1
5
4
8
82
A2
A3
6
3
2
4
4
6
8
8
1
2
3
4
7
8
INTERNAL
CONNECTION
7
2
6
8
1
1
4
4
7
8
INTERNAL
CONNECTION
7
2
6
2
1
5
4
8
7
2
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
10
L-Series Series - Lamp Circuit Diagrams
ILLUMIN.
SCHEMATIC
CODE
ILLUMIN.
CODE
SCHEMATIC
-9
+4
+1
-9
J
1
2
A
1
1
2
+10
-11
-12
INTERNAL
CONNECTION
B
2
2
+10
+12
-9
-12
INTERNAL
CONNECTION
C
1
1
2
+10
+10
-9
+12
+4
(–)9
D
E
F
1
K
1
(+)10
-9
+4
1
2
LEGEND
DEFINITION
TERMINAL LOCATION
SYMBOL
+10
-9
+8
LAMP LOCATION
MAINTAINED CIRCUIT
MOMENTARY CIRCUIT
1
2
+10
-9
INTERNAL CONNECTION
(JUMPER TERMINAL)
+4
2 POSITION CONNECTION
G
H
2
1
P3
P1
2 POSITION
+10
-9
P2
P1
P3
3 POSITION
2
1
+10
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
11
* Intentionally left blank
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
@
Email: sales carlingtech.com
@
Northern Region Sales Office: nrsm carlingtech.com
@
Southeast Region Sales Office: sersm carlingtech.com
@
Midwest Region Sales Office: mrsm carlingtech.com
@
West Region Sales Office: wrsm carlingtech.com
@
Latin America Sales Office: larsm carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
@
Email: sales carlingtech.com.hk
@
Shenzhen, China: shenzhen carlingtech.com
@
Shanghai, China: shanghai carlingtech.com
@
Pune, India: india carlingtech.com
@
Kaohsiung, Taiwan: taiwan carlingtech.com
@
Yokohama, Japan: japan carlingtech.com
|
|
Europe Middle East Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
@
Email: ltd.sales carlingtech.com
@
Germany: gmbh carlingtech.com
@
France: sas carlingtech.com
www.carlingtech.com
REV_03_2015
相关型号:
L1713S04-BZ00-000
Rocker Switch, SPDT, On-off-(on), Momentary, Quick Connect Terminal, Rocker Actuator, Panel Mount
Carling Techn
L1716A/BLUE
Circular Connector, 1 Contact(s), Polyvinylchloride, Male, Crimp Solder Terminal, Plug
DIALIGHT
L1716A/GREEN
Circular Connector, 1 Contact(s), Polyvinylchloride, Male, Crimp Solder Terminal, Plug
DIALIGHT
L1716A/RED
Circular Connector, 1 Contact(s), Polyvinylchloride, Male, Crimp Solder Terminal, Plug
DIALIGHT
L1716A/YELLOW
1 CONTACT(S), POLYVINYLCHLORIDE, MALE, CIRCULAR CONNECTOR, CRIMP SOLDER, PLUG
DIALIGHT
©2020 ICPDF网 联系我们和版权申明